KitchenAid Oven Thermal Fuse Blown? A Spring, TX Repair Story

PowerOn technician replacing the cooling fan on a KitchenAid built-in wall oven in Spring, TX

A KitchenAid wall oven in Spring, TX went completely dead with a blank screen. The thermal fuse had blown, but the real cause was a cooling fan that had stopped running. Here’s how the two parts work together, why self-clean before the holidays sets this off, and how to protect your oven.

Sub-Zero Refrigerator Drawers Not Cooling in The Woodlands?

Technician replacing the condenser fan motor on Sub-Zero undercounter refrigerator drawers in a Carlton Woods kitchen, The Woodlands, TX

A set of Sub-Zero 24″ Designer undercounter refrigerator drawers in Carlton Woods stopped cooling, and warm air was coming from under the unit. The condenser fan motor had died. Here’s how to spot the same problem and why turning the unit off can save your compressor.

Sub-Zero Fridge Not Cooling in The Woodlands? Check the Fan Switch

echnician holding a replacement Sub-Zero refrigerator fan door switch below the original switches on a refrigerator in The Woodlands, TX

A Sub-Zero in The Woodlands, TX stopped cooling in the refrigerator section, and the cause turned out to be a small fan door switch, not the fan or compressor. Here’s how that switch works, the other common reasons a Sub-Zero stops cooling, and the simple test you can do first.

Thermador Ice Maker Leaking? Water Valve Fix in Creekside Park

Thermador built-in ice maker removed with frozen fill cup, The Woodlands TX

A built-in Thermador refrigerator in Creekside Park had water leaking inside the freezer. The ice maker fill cup kept freezing because the water valve never fully shut off, so every new fill overflowed. We replaced the valve and also fixed a broken dispenser line under the freezer door.

Dacor Vent Hood Not Turning On? A Corroded Ribbon Was the Culprit

Dacor vent hood opened for diagnosis with control board exposed in an outdoor kitchen in Montgomery, TX

This Dacor vent hood sat dead for months: no fan, no lights, no buttons. Power and the control board checked out fine. The real problem was moisture corrosion on the common line of the button panel ribbon. Here’s how we found it, how we fixed it, and how to keep it from happening to your hood.